BUDZAR



Contact: Sales Manager

38241 Willoughby Pkwy
Willoughby, OH 44094
US-Ohio

Phone: 440-918-0505
Fax: 440-918-0606

Website

E-mail

Budzar Industries specializes in process fluid heat transfer systems. Since 1975, Budzar Industries has earned a reputation for quality and ingenuity in the design, engineering, and manufacturing of temperature control systems. Today, Budzar systems can be found throughout the world bringing accurate temperature measurement and control to the production of: chemicals, petroleum, plastics, rubber, paper, power, steel, food, and pharmaceuticals. 

Budzar designs and manufactures temperature control equipment for the: Chemical, Food, Metal Working, Paper, Petroleum, Pharmaceutical, Power, Plastic, Rubber, Steel and Web Industries. Typical applications include: 

Chemical and Pharmaceutical

* Chemical Reactor Temperature Control Units from -100 to 700F. 
* Fluid Heating Systems for Pastillators and Jacketed Piping Systems to 650F. 
* Central Chilled Fluid Systems to -40F. 
* Central Thermal Fluid Heater Systems to 650F. 
* Pilot Plant and Kilo Lab Systems for Recirculating Fluid Temperatures from -100 to 700F. 
* Recirculating Batch Temperature Control Systems for Fermentation Vessels. 
* Vent Condenser Cooling Systems. 
* Rotary Cone Dryer and Tray Dryer Heating Systems to 700F. 
* Biowaste Decontamination Systems. 

Semi-Conductor 

* Central Cooling Water Systems in stainless steel, PE, PVC and PVDF construction. 
* Local Temperature Control Skids in stainless steel, PE, PVC and PVDF construction. 

Paper

* Head Box Temperature Control Systems. 
* Calender and SuperCalender Temperature Control Systems to 400F. (Steam/Electric Fired). 
* Soft Calender Temperature Control Systems to 650F (Electric/Fossil Fuel Fired). 
* Chilled Air Handling Systems (Edge Cooling Systems). 
* Roll Cooling Systems for Coating Systems. 

Rubber

* Banbury Mixer Temperature Control. 
* Waste Oil Recovery and Recycling. 
* Extruder Temperature Control. 
* Cooling Troughs. 
* Mill Temperature Control. 
* Calendar Temperature Control. 
* Central Chiller and Cooling Towers for plant wide cooling utilities. 
* Compression Molding Temperature Control. 
* Tire Building Temperature Control. 

Plastics

* Injection Molding. 
* Mold Temperature Controllers, Single-Zone, Multi-Zone, and Sliding Tray Systems. 
* Portable Chillers. 
* Central Chillers. 
* Negative Pressure Mold Temperature Controllers. 
* Blow Molding Temperature Control. 
* RIM Temperature Control. 
* Blown Film Temperature Control. 
* Profile Extrusion Temperature Control. 
* Vacuum Sizing Table Temperature Control. 
* Cooling Trough Temperature Control. 
* Slush Molding Temperature Control. 
* Portable Chillers. 
* Central Chillers. 
* Cooling Towers. 
* Pump Tank Sets. 
* Central System Engineering, Design, and Supply 

Web Applications

* Plastic Film Temperature Control. 
* Cast Film Line Temperature Control. 
* Plastic Sheet Production Temperature Control. 
* Plastic Packaging Production Temperature Control. 
* Textiles Line Temperature Control. 
* Non-Wovens Temperature Control. 
* Photographic Paper Production Temperature Control. 
* All Heat Transfer Roll Applications. 
* Complete Systems Integrated With F.R. Gross Rolls. 
PORTABLE HOT OIL UNITS
Tired of leaky units that burn oil and pollute your machinery? OTP Series leak-free portable hot-oil units are built with welded piping to prevent leaks and offer: 

1. Dedicated source of high-temperature fluid 
2. Safety control to maintain fluid integrity and ensure the safety of your employees 

MOLD TEMPERATURE CONTROLLERS
Optimize your injection molding and operation productivity with our MTC Portable Hot Water Units, featuring total temperature control including: 

1. Small footprint & stackable design 
2. 5 year controller warranty with continuos auto-tune 
3. Temperature accuracy to ±1F 
4. Continuous automatic air vent eliminates heater failure 
5. High temperature pump seal wipes out seal failures and leaks 

MULTI-ZONE HOT
WATER UNITS
Ideal for extruders, injection molders and other processes requiring multiple fluid temperatures up to 250F., MWT Series Multi-Zone Hot Water Units offer: 

1. Up to eight individual temperature control zones 
2. Each zone has its own microprocessor controller, pump, heater and cooling mode 
3. Available in steam or electric operation 

MIXER TEMPERATURE CONTROL UNITS
MXR Series intensive mixer temperature control systems provide multi-zone fluid heat-transfer for separate temperature control of mixer sides, rotors, and drop door: 

1. Microprocessor control and modulating control valves for reliable, accurate operation 
2. NEMA 12 dust-tight electrical components and enclosures withstand mixer-room atmospheres 
 
HIGH VOLUME HOT
WATER UNITS
Achieve temperature control up to 300F for your Mill, Calender, Reactor or other high capacity process load with the HWT Series high volume, water temperature control systems, featuring: 

1. Single-zone, dual-zone or multi-zone systems 
2. Operate with plant steam or electricity as the heat source 
 
STATIONARY HOT OIL UNITS
The OTS Series stationary hot-oil units incorporate an all welded design to prevent leaks and provide unparalleled safety for your employees and operation, while supplying these exceptional benefits: 

1. Dedicated source of high-temperature fluid 
2. Keep your primary process equipment clean and efficient with low watt density heaters that prevent oil degradation 

NEGATIVE PRESSURE
HOT WATER   
NEGATIVE PRESSURE
HOT OIL 
Budzar's Thermal VAC Hot Water & Hot Oil Series feature an on-board vacuum pump to draw heat transfer fluid through your mold rather than forcing it through the process with pressure like conventional temperature control units. Negative pressure units feature volumes of benefits: 

1. Continue to run cracked molds safely until maintenance can be scheduled 
2. Evacuates your mold of all hot water and hot oil proir to mold changes 
3. Accelerates mold change overs 
4. Improves operator safety by reducing the risk of accidental hot fluid spray 

LUBRICATING OIL SYSTEMS 
1. Air or water-cooled modules complete with reservoir, pump, filter and oil cooler 
2. Available for use with plant steam or electricity as a pre-heat source 
3. Designed for indoor or outdoor installation and operating oil temperatures up to 200F 
4. Capacities from 1 to 30 GPM 

OIL WEIGH SYSTEMS 
Fully automated oil weightment and injection systems for up to eight separate oils. Stand alone or integratable with your mixer control system. 

MIXER WASTE OIL
RECOVERY SYSTEM 
Eliminate costly waste oil collection and disposal with the Budzar Mixer Waste Oil Recovery Systems. 

Pump Tank Systems
 
TOWER TANK SYSTEMS 
 
CHILLER TANK SYSTEMS The CTS Chiller Pump-Tank Systems and TTS Pump- Tank Systems provide the reservoirs and pumping decks for central chillers and cooling towers, featuring: 

1. Dual reservoirs with heavy gauge, sand-blasted and epoxy-tar coated mild steel to prevent corrosion (Stainless construction available) 
2. CTS Systems designed for use with Budzar central chiller modules
3. TTS Systems designed for use with Budzar or other cooling towers, prevent tower water freeze-up
4. Both systems suitable for single, dual and standby-pump configurations
5. High-volume process pumps maximize process-temperature stability 
6. Dedicated chiller pumps maximize the efficiency of your central chiller

Portable Chillers
 
PORTABLE CHILLERS Budzar's ICE AC (air-cooled) and WC (water-cooled) are built for top performance and engineered for bottom-line control with an array of advantages:

1. Microprocessor controls maintain temperatures to within±1¡ F or better 
2. System design conservers plant floor space while allowing for easy mainenance access 
3. Copeland compressors- most sizes utilize efficient scroll compressors ---

Central System Chillers

CENTRAL SYSTEM 
WATER-COOLED CHILLERS 

AIR-COOLED OUTDOOR PACKAGED WATER CHILLERS  Central System Chillers feature several configurations: 

1. Indoor, air-cooled, modular AM Series Chillers for industrial cooling applications without a separate source of condenser supply water recover energy costs through supplemental plant heating in the winter and ventilation in the summer 

2. Outdoor, air-cooled, modular AMO Series Chillers for industrial cooling applications with limited floor space can be located on ground-level pads or the plant roof 

3. Indoor, water-cooled modular WM Series use a separate source of condensing water All units are modular enabling you to purchase what you need and add as your requirements grow. All units are designed for use with Budzar CTS Pump-Tank systems, delivering chilled water throughout your plant. 

Cooling Towers

VERTICAL FLOW
COOLING TOWERS 
CROSS FLOW 
COOLING TOWERS 
CP, CT and NC Series Cooling Towers work with Budzar TTS Tower Pump Tank Systems to provide cooling water for industrial processes. 

SELF-CONTAINED CHILLERS

SELF-CONTAINED INDOOR
AIR-COOLED CHILLERS 

SELF-CONTAINED WATER-COOLED CHILLERS 

DUAL-CIRCUIT WATER-COOLED CHILLER  Self-contained AP (air-cooled), WP (water-cooled) are "mini-central" systems that combine chiller and pump tank systems into one easy-to-install unit, offering: 

1. High-volume process pump to minimize process temperature gradients 
2. Dedicated chiller pump sized to maximize chiller efficiency 
3. Completely redundant circuits in Gemini Chillers, guaranteeing at least 50% chiller capacity